Fire Classification |
UL790-98 |
Passed –
Class A with VersaShield
Underlayment
Passed –
Class B with #30 ASTM Type II Felt Underlayment |
|
Impact
Resistance |
FM-4473
|
TPassed - Class 4
|
|
Landfill
and Env. Leach Test |
TCLP–EPA1311-92
|
Passed - no
toxic or harmful substance detected. |
|
110mph
Wind Test |
ASTM
D3161-03b |
Passed – Class
F with 4 ring-shank nails |
|
Burning
Rate |
ASTM
D635-98 |
Passed |
|
Ignition
Properties |
ASTM
D1929 |
Ignition Temp –
788oF |
|
Smoke
Density |
ASTM
D2843-99 |
Passed - Smoke
Density Rating 4.5% |
|
Wind
Uplift |
TAS125-03, UL 580 |
Passed – Class
90 |
|
Uplift
Bend |
AC07-02
§3.2.3 |
Passed
|
|
Penetration Test |
AC07-02
§3.2.4 |
Passed
|
|
Temperature Cycling Test |
AC07-02
§3.2.6 |
Passed
|
|
Wind
Driven Rain, Dade County Wind Test |
AC07-02
§3.2.7, TAS 100-95 |
Passed |
|
UV
Weathering Test |
ASTM
G26-96 |
Passed - ICC ES
AC07 2000 Hr |
|
QLab UV
Test |
ASTM
D5722 |
2000 Hr.
Completed |
|
Panel
Stacking Test |
5000 lb load at
150F for 48 hrs. |
No problem
detected |
|
Decay
Resistance |
ASTM
D1413-99, D2017-81 |
No
problem detected |
|
Rain
Leak Test |
Continuous water spray for 48 hrs. on 2:12 slope |
Passed – no
leakage |
|
Algae
Test |
Exposure to Cyanophyta
|
Passed – no permanent
stain |